Lower energy spend
10 to 20%
less site energy
Brightcore EDGE™ cooling for data centers
Brightcore's next-generation geothermal cooling solution for new and existing data centers reduces the power required for cooling which in turn unlocks additional compute capacity.
Power
75 to 85%
Reduction in peak cooling power
Compute
10 to 20%
Increase in compute, same site power
Efficiency
1.09pPUE
Improvement vs. 1.30 to 1.43 conventional
Water
0WUE
Eliminated with fully closed-loop cooling
The problem
At up to 35% of total site energy, cooling is the largest non-IT data center load. Every megawatt spent on cooling is a megawatt of compute that cannot be monetized.
The solution
Brightcore EDGE™ is a hybrid cooling platform that delivers the lowest watt-per-token cooling available by optimizing geothermal cooling with dry coolers and optional chillers. Stop relying on outdoor air for heat rejection when conventional equipment is least efficient.
25–35%
4–6%
The result
Same Site. Same Power. Nineteen percent more compute.


Illustrative example: 250 MW IT facility in TX
Bars drawn to scale against total site power
How it works
Conventional cooling systems reject heat to outdoor air, so they work hardest on the hottest days. Brightcore EDGE™ sends heat into naturally cool ground using only pumps and underground piping. Dry coolers and optional chillers run when conditions favor them. Brightcore EDGE™ software determines the most efficient option at every moment.
Reads live load, equipment, and weather data.
Forecasts cooling demand and outdoor conditions.
Operates geothermal, dry coolers, and chillers.
Ground temperature is tracked across seasons and years to keep the borefield in balance.
System design
The Result: Geothermal for any geography, site, and scale.

Economics
10 to 20%
less site energy
75 to 85%
cooling power reduction
Illustrative example
Deployment
Modular borefield design means installation happens in phases so cooling comes online as it gets built, minimizing speed to first token.
6months
to install a borefield for a 250 MW-IT site
Site assessment
Design
Phased drilling and installation
Commissioning
Additional benefits
0 WUE
Fully closed loop.
Chillers optional
Reduce or remove them entirely.
Reduce noise
50 to 85% fewer dry coolers/chillers.
24/7/365
100 percent of the cooling load, every hour.
Fewer moving parts
Fewer failure points. Less maintenance.
50 year+
Asset life. No replacement cycle.
About Brightcore
Brightcore Energy is a leading clean energy solutions provider based in Armonk, NY. We plan, design, build, and manage geothermal and other energy efficiency projects for large commercial and institutional clients.
Recognition
Comparable upfront cost. Lower ongoing cost.
No land beyond your site. The bores run below grade, under parking lots and buildings.
Yes. Heat goes into the ground, which stays cooler than the air. Brightcore EDGE™ works in all geographies.
The borefield takes the peak. The rest of the system works around it, so the full cooling load is met.
Yes. Brightcore EDGE™ works with your existing cooling architecture and can be phased in while the site stays live.
Six months for a 250 MW borefield.